**Ask More Questions About This Truck**
**Ask More Questions About This Truck**
Truck Details
1994 Pierce Arrow 100' Platform
Pierce Arrow Chassis
Seating for 4; 3 SCBA seats
Detroit 500 HP Diesel Engine
Allison HT740 Automatic Transmission
Engine Brake
Waterous CMU 1500 GPM Pump
300 Gallon Polypropylene Tank
Last Pump Certification: 10/2015
Driver's Side Discharges: (2) 2 1/2"
Driver's Side Suction: (1) 6", (1) 2 1/2"
Officer's Side Discharge: (2) 2 1/2", (1) 4"
Officer's Side Suction: (1) 6", (1) 2 1/2"
Monitor on Platform
Crosslays/Speedlays: (1) 2 1/2", (2) 1 1/2"
Onan 6KW Hydraulic Generator
Air Conditioning
Aluminum Hose Bed Cover
Ground Ladders
Engine Hours: 4,612
Mileage: 30,729
Telescoping Lights
Pierce : 100' Aerial Device
Last Aerial Certification: 11/2016
Additional equipment not included with purchase.
With under 50,000 miles, this piece of apparatus has lots of life remaining to respond to emergencies in your department.
At Pierce Manufacturing, we build trucks that live up to your demands. It’s not some nine-to-five-go-home-and-forget-about-it kind of thing. Too much rides on what you do. To our team, there is no room for anything less than the absolute best. What began in 1913, building truck bodies on Model T Ford chassis in an old converted church, has evolved to creating highly customized, carefully designed and engineered pumpers, aerials, tankers and rescue units that have no equal. Behind every Pierce truck is a team of professionals whose mission is to build your truck, exactly how you ordered it. To us, every step of the process is personal; from innovation and expertise, to the customization and service. When the best people you know are the very people you serve, there is only room for exceptional.
https://www.piercemfg.com/pierce/history/timeline
Changes in NFPA in 1991 significantly increased fire fighter's safety when operating a fire truck. Buying a used fire apparatus newer than this year will bring those safety features into your firehouse as well. The enclosed cab which was required in 1991 and forward brought fire fighters out of the elements of weather, and into the safety of the fire apparatus cab.
Stock#: 11826
Pierce Arrow Chassis
Seating for 4; 3 SCBA seats
Detroit 500 HP Diesel Engine
Allison HT740 Automatic Transmission
Engine Brake
Waterous CMU 1500 GPM Pump
300 Gallon Polypropylene Tank
Last Pump Certification: 10/2015
Driver's Side Discharges: (2) 2 1/2"
Driver's Side Suction: (1) 6", (1) 2 1/2"
Officer's Side Discharge: (2) 2 1/2", (1) 4"
Officer's Side Suction: (1) 6", (1) 2 1/2"
Monitor on Platform
Crosslays/Speedlays: (1) 2 1/2", (2) 1 1/2"
Onan 6KW Hydraulic Generator
Air Conditioning
Aluminum Hose Bed Cover
Ground Ladders
Engine Hours: 4,612
Mileage: 30,729
Telescoping Lights
Pierce : 100' Aerial Device
Last Aerial Certification: 11/2016
Additional equipment not included with purchase.
With under 50,000 miles, this piece of apparatus has lots of life remaining to respond to emergencies in your department.
At Pierce Manufacturing, we build trucks that live up to your demands. It’s not some nine-to-five-go-home-and-forget-about-it kind of thing. Too much rides on what you do. To our team, there is no room for anything less than the absolute best. What began in 1913, building truck bodies on Model T Ford chassis in an old converted church, has evolved to creating highly customized, carefully designed and engineered pumpers, aerials, tankers and rescue units that have no equal. Behind every Pierce truck is a team of professionals whose mission is to build your truck, exactly how you ordered it. To us, every step of the process is personal; from innovation and expertise, to the customization and service. When the best people you know are the very people you serve, there is only room for exceptional.
https://www.piercemfg.com/pierce/history/timeline
Changes in NFPA in 1991 significantly increased fire fighter's safety when operating a fire truck. Buying a used fire apparatus newer than this year will bring those safety features into your firehouse as well. The enclosed cab which was required in 1991 and forward brought fire fighters out of the elements of weather, and into the safety of the fire apparatus cab.
Stock#: 11826
General Specs
- Stock#: 11826
- 1994
- Pierce Arrow Chassis
- Pierce
- Seating for 4; 3 SCBA seats
- Custom
- Mileage: 30,729
- Engine Hours: 4,612
- Detroit 500 HP Diesel Engine
- Engine Brake
- Allison HT740 Automatic Transmission
Pump
- Waterous CMU 1500 GPM Pump
- 300 Gallon Polypropylene Tank
- Driver's Side Discharges: (2) 2 1/2"
- Crosslays/Speedlays: (1) 2 1/2", (2) 1 1/2"
- Officer's Side Discharge: (2) 2 1/2", (1) 4"
- Driver's Side Suction: (1) 6", (1) 2 1/2"
- Officer's Side Suction: (1) 6", (1) 2 1/2"
- Monitor on Platform
- Last Pump Certification: 10/2015
Electrical
- Onan 6KW Hydraulic Generator
- Telescoping Lights
- Air Conditioning
- Aluminum Hose Bed Cover
- Good
- Ground Ladders: Ground Ladders
Options
- Pierce : 100' Aerial Device

Apparatus currently resides in
USA - Northeast
$49,000
For Additional Information,
Contact Brindlee Mountain at
Local : 256.776.7786 or
**Ask More Questions About This Truck**
$49,000
For Additional Information,
Contact Brindlee Mountain at
Local : 256.776.7786 or
Don't like this one? Check out these other 4 options
Call Now
$49,000
1994 Pierce Arrow 100' Platform
Similar Trucks
2007 Pierce Dash 100' Quint

Waterous 1500 GPM Pump, 500 Gallon Tank, Foam System, Cummins Diesel
Truck Detail